Dell PowerEdge R7615 - PERC Module; Removing the Rear Mounting Front PERC Module

Dell PowerEdge R7615
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 97. 24 x 2.5 inch U.2 drives Gen5 Single Width
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 92. 24 x 2.5 inch U.2 drives Gen5 Single Width
Order From To
1 SL4_CPU1_PB2 (signal connector on
system board)
CTRL_DST_PB2 (fPERC input
connector)
2 SL2_CPU1_PB2 (signal connector on
system board)
CTRL_DST_PA2 (fPERC input
connector)
3 SIG_PWR_1 (system board power
connector)
BP_PWR_2 (backplane power
connector)
4 SL3_CPU1_PB2 (signal connector on
system board)
CTRL_DST_PA1 (fPERC input
connector)
5 SL1_CPU1_PB2 (signal connector on
system board)
CTRL_DST_PA1 (fPERC input
connector)
6 SIG_PWR_1 (system board power
connector)
BP_PWR_1 (backplane power
connector)
PERC module
This is a service technician replaceable part only.
Removing the rear mounting front PERC module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the cooling fan cage assembly.
Installing and removing system components