Steps
1. Align the connectors and guide slots on the rear mounting front PERC module with the connectors and guide pins on the
drive backplane.
2. Slide the rear mounting front PERC module until the module is connected to the drive backplane.
3. Using a Phillips #2 screwdriver, tighten the captive screws on the rear mounting front PERC module.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 99. Installing the rear mounting front PERC module
Next steps
1. Connect all the cables, observe the cable routing.
2. Install the cooling fan cage assembly.
3. If removed, install the air shroud or install the GPU air shroud.
4. Install the drive backplane cover.
5. Follow the procedure listed in After working inside your system.
Removing the front mounting front PERC module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the cooling fan cage assembly.
4. Remove the drive backplane cover.
5. If required, remove the air shroud or remove the GPU air shroud..
6. If required, remove the drive backplane cover.
7. Disconnect all the cables, observe the cable routing.
NOTE: Refer Cable routing topic for more information.