Library logs
Select Service Library > View Library Logs to display a log history summary of errors that occurred.
The error log is displayed with sense data information. The summary can be filtered to display errors
with specific sense data code types.
Click Refresh to read the log of errors from the tape library. You can select an error in the Index List
panel to display data specific to that error in the Detail panel.
The information that is displayed for the error comprises:
v Index number of the error
v Date and time the error occurred
v Error code
v Description of the error
There are two types of error data that are displayed in the library log with different Code attributes:
v Library/Drive sense data (Sense key/ASC/ASCQ)
For example, a 5/3B/0D error states that an illegal request was initiated that resulted in a “medium
destination element full” error that is reported by the library. Selecting log entry 012 provides detailed
sense data for this failure. Information about sense data is listed in Appendix C, “Sense data,” on page
135.
v Library/Drive error code ([Code])
For example, in log entry 010, a [0222] error states that the library cannot eject medium because drive
is in state of Prevent Media Removal. Information about errors and action to resolve the problem are
listed in Appendix A, “Error codes,” on page 115.
a29z0131
Figure 100. View Library Logs screen