A storage element address is assigned to each cartridge at the time the cartridge is inserted. Storage
element addresses range from 4097 to 4105 (0x1001 to 0x1009) when the I/O station is not enabled, and
from 4097 to 4104 (0x1001 to 0x1008) when the I/O station is enabled.
Library specifications
Table 6. Physical specifications
Parameter Measurement
Front panel width (chassis/bezel) 445 mm (17.52 in.)/483 mm (19.02 in.)
Depth 850 mm (33.46 in.)
Height 44 mm (1.73 in.)
Weight (library only) 13 kg (28.66 lbs)
Table 7. Electrical specifications
Parameter Measurement
Voltage 100 - 240 Vac. (4.0 to 1.5 A)
Frequency 50 - 60 Hz
Power consumption 110 W
For more information about installation specifications, see “Installation and configuration” on page 21.
Table 8. Environmental specifications
Parameter Operating (see Note) Storage Shipping
Temperature 10 - 38 °C (50 - 100 °F) 1 - 60 °C (34 - 140 °F) -40 to 60 °C (-40 to 140 °F)
Temperature variation 10 °C/hour (maximum) 10 °C/hour (maximum) 10 °C/hour (maximum)
Relative humidity 20 - 80% 10 - 90% 10 - 90%
Wet bulb temperature 26 °C (78.8 °F) maximum 29 °C (84 °F) maximum 29 °C (84 °F) maximum
Altitude (meters) 0 - 2,500 0 - 2,500 0 - 2,500
Front Rear
Reservedslot
Column4
Tier2
Column3
Tier2
Column2
Tier2
Column1
Tier2
Column5
Tier1
Column4
Tier1
Column3
Tier1
Column2
Tier1
Column1
Tier1
Drive
Accessor
Column5
Tier2
Figure 7. Location coordinates