Network Administration: sFlow 325
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Dell Astute\User
Guide\Dell_Astute_Network_Admin_sFlow.fm
DELL CONFIDENTIAL – PRELIMINARY 8/9/16 - FOR PROOF ONLY
Global
— A globally unique IPv6 address; visible and reachable
from different subnets.
IP Address
— Enter the receiver’s IP address.
4
Enter the fields:
UDP Port
— Port to which SYSLOG message are sent.
Maximum Datagram Size (Bytes)
— Maximum number of bytes that
can be sent to the receiver in a single sample datagram (frame).
sFlow Interface Settings
To sample datagrams or counters from a port, the port must be associated
with a receiver. sFlow port settings can be configured only after a receiver has
been defined in the
sFlow Receiver Settings
pages.
To enable sampling and configure the port from which to collect the sFlow
information:
1
Click
Network Administration > sFlow
>
sFlow Interface Settings
.
The sflow interface settings are displayed.
2
To associate an sFlow receiver with a port, click
Edit, Add
, and enter the
fields:
Interface Type
— Displays the interface type, which is Port.
Interface
— Select the port from which information is collected.
Flow Sampling
— Enable/disable flow sampling. Flow sampling
cannot be disabled if
Counters Sampling
is disabled.
Flow Sampling Average Sampling Rate
— If x is entered, a flow
sample will be taken for each x frames.
Flow Sampling Receiver Index
— Select one of the indices that was
defined in the sFlow Receiver Settings pages.
Flow Sampling Maximum Header Size (Bytes)
— Maximum number
of bytes that should be copied from a sampled packet.
Counters Sampling
— Enable/disable counters sampling. Flow
sampling cannot be disabled if
Flow Sampling
is disabled
Counters Sampling Interval (Sec)
— If x is entered, this specifies that
a counter sample will be taken for each x seconds.