ASDA-B2-F Control Mode of Operation
September, 2015 6-17
6
Generally, instrument is needed when applying frequency domain for measurement. Users are
required to adopt the measurement techniques; while time domain only needs a scope and goes
with the analog input/output terminal provided by the servo drive. Thus, time domain is frequently
used to adjust PI controller. The abilities of PI controller to deal with the resistance of torque load
and the following command are the same.
That is to say, the following command and resistance of torque load have the same response
performance in frequency domain and time domain. Users can reduce the bandwidth by setting
the low-pass filter in command end.
Auto Mode
Auto mode adopts adaptive principle. The servo drive automatically adjusts the parameters
according to the external load. Since the adaptive principle takes longer time, it will be unsuitable
if the load changes too fast. It would be better to wait until the load inertia is steady or changes
slowly. Depending on the speed of signal input, the adaptive time will be different from one
another.
W
J
馬達轉速
慣量估測
If the KVF value closes to 1, the feed forward
compensation will be more complete and the
dynamic following error will become smaller.
However, if the KVF value is set to be too big,
it would cause vibration.
Motor Speed
Inertia Measurement

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-B2-F Series and is the answer not in the manual?

Delta ASDA-B2-F Series Specifications

General IconGeneral
BrandDelta
ModelASDA-B2-F Series
CategoryServo Drives
LanguageEnglish

Related product manuals