Parameters ASDA-B2-F
7-62 September, 2015
7
P5-31 AC11 Acceleration / Deceleration Time (Number #11)
ddress: 053EH
053FH
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 3000
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-32 AC12 Acceleration / Deceleration Time (Number #12)
ddress: 0540H
0541H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 5000
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-33 AC13 Acceleration / Deceleration Time (Number #13)
ddress: 0542H
0543H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 8000
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-34 AC14 Acceleration / Deceleration Time (Number #14)
ddress: 0544H
0545H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 50
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 1500
Format DEC Data Size: 16-bit
Settings:
The default value of this parameter is smaller (short deceleration time) and it is used for deceleration
time setting of auto protection.
P5-35 AC15 Acceleration / Deceleration Time (Number #15)
ddress: 0546H
0547H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 30
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 1200
Format: DEC Data Size: 16-bit
Settings:
The default value of this parameter is smaller (short deceleration time) and it is used for deceleration
time setting of auto protection.
Note:
The default value of this parameter is smaller, which can be used in high-speed deceleration.