Chapter 10 Digital KeypadC2000
10-25
Other display
When a fault occurs, the menu will display:
ocA
Oc at accel
Fault
CE01
Comm. Error 1
Warning
1. Press STOP / RESET button to reset the fault code. If still no response, please contact local distributor or return
to the factory. To view the fault DCBUS voltage, output current and output voltage, press “MENU”“Fault
Record”.
2. After resetting, if the screen returns to main page and shows no fault after pressing ESC, the fault is cleared.
3. When fault or warning message appears, backlight LED will blink until the fault or the warning is cleared.
Optional accessory: RJ45 Extension Lead for Digital Keypad
Part No. Description
CBC-K3FT RJ45 extension lead, 3 feet (approximately 0.9m)
CBC-K5FT RJ45 extension lead, 5 feet (approximately 1.5 m)
CBC-K7FT RJ45 extension lead, 7 feet (approximately 2.1 m)
CBC-K10FT RJ45 extension lead, 10 feet (approximately 3 m)
CBC-K16FT RJ45 extension lead, 16 feet (approximately 4.9 m)
Note: When you need to buy communication cables, buy non-shielded, 24 AWG, 4 twisted pair, 100 ohms
communication cables.

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
BrandDelta
ModelC2000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals