EasyManua.ls Logo

Delta C2000 Series - Basic Parameters

Delta C2000 Series
936 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 11 Summary of Parameter SettingsC2000
11-10
01 Basic Parameters
Pr. Parameter Name Setting Range Default
01-00 Maximum operation frequency 0.00–599.00 Hz
60.00 /
50.00
01-01 Output frequency of motor 1 0.00–599.00 Hz
60.00 /
50.00
01-02 Output voltage of motor 1
230V: 0.0–255.0 V
460V: 0.0–510.0 V
575V: 0.0–637.0 V
690V: 0.0–765.0 V
200.0
400.0
575.0
660.0
01-03 Mid-point frequency 1 of motor 1 0.00–599.00 Hz 3.00
01-04 Mid-point voltage 1 of motor 1
230V: 0.0–240.0 V
460V: 0.0–480.0 V
575V: 0.0–637.0 V
690V: 0.0–720.0 V
11.0
22.0
0.0
0.0
01-05 Mid-point frequency 2 of motor 1 0.00–599.00 Hz 1.50
01-06 Mid-point voltage 2 of motor 1
230V: 0.0–240.0 V
460V: 0.0–480.0 V
575V: 0.0V–637.0 V
690V: 0.0–720.0 V
5.0
10.0
0.0
0.0
01-07 Min. output frequency of motor 1 0.00–599.00 Hz 0.50
01-08 Min. output voltage of motor 1
230V: 0.0–240.0 V
460V: 0.0–480.0 V
575V: 0.0–637.0 V
690V: 0.0–720.0 V
1.0
2.0
0.0
0.0
01-09 Start-up frequency 0.00–599.00 Hz 0.50
01-10 Output frequency upper limit 0.00–599.00 Hz
599.00
01-11 Output frequency lower limit 0.00–599.00 Hz
0
01-12 Acceleration time 1
Pr. 01-45=0: 0.00–600.00 sec.
Pr. 01-45=1: 0.00–6000.0 sec.
The default of motor drive with 30HP and above:
60.00 / 60.0
10.00
01-13 Deceleration time 1
Pr. 01-45=0: 0.00–600.00 sec.
Pr. 01-45=1: 0.00–6000.0 sec.
The default of motor drive with 30HP and above:
60.00 / 60.0
10.00
01-14 Acceleration time 2
Pr. 01-45=0: 0.00–600.00 sec.
Pr. 01-45=1: 0.00–6000.0 sec.
The default of motor drive with 30HP and above:
60.00 / 60.0
10.00
01-15 Deceleration time 2
Pr. 01-45=0: 0.00–600.00 sec.
10.00