Chapter 11 Summary of Parameter SettingsC2000
11-24
04 Multi-step Speed Parameters
Pr. Parameter Name Setting Range Default
04-00 1
st
step speed frequency
0.00–599.00Hz
0.00
04-01 2
nd
step speed frequency 0.00–599.00Hz 0.00
04-02 3
rd
step speed frequency 0.00–599.00Hz 0.00
04-03 4
th
step speed frequency 0.00–599.00Hz 0.00
04-04 5
th
step speed frequency 0.00–599.00Hz 0.00
04-05 6
th
step speed frequency 0.00–599.00Hz 0.00
04-06 7
th
step speed frequency 0.00–599.00Hz 0.00
04-07 8
th
step speed frequency 0.00–599.00Hz 0.00
04-08 9
th
step speed frequency 0.00–599.00Hz 0.00
04-09 10
th
step speed frequency 0.00–599.00Hz 0.00
04-10 11
th
step speed frequency 0.00–599.00Hz 0.00
04-11 12
th
step speed frequency 0.00–599.00Hz 0.00
04-12 13
th
step speed frequency 0.00–599.00Hz 0.00
04-13 14
th
step speed frequency 0.00–599.00Hz 0.00
04-14 15
th
step speed frequency 0.00–599.00Hz 0.00
04-15 Position command 1 (rotation) -30000–30000 0
04-16 Position command 1 (pulse) -32767–32767 0
04-17 Position command 2 (rotation) -30000–30000 0
04-18 Position command 2 (pulse) -32767–32767 0
04-19 Position command 3 (rotation) -30000–30000 0
04-20 Position command 3 (pulse) -32767–32767 0
04-21 Position command 4 (rotation) -30000–30000 0
04-22 Position command 4 (pulse) -32767–32767 0
04-23 Position command 5 (rotation) -30000–30000 0
04-24 Position command 5 (pulse) -32767–32767 0
04-25 Position command 6 (rotation) -30000–30000 0
04-26 Position command 6 (pulse) -32767–32767 0
04-27 Position command 7 (rotation) -30000–30000 0
04-28 Position command 7 (pulse) -32767–32767 0
04-29 Position command 8 (rotation) -30000–30000 0
04-30 Position command 8 (pulse) -32767–32767 0
04-31 Position command 9 (rotation) -30000–30000 0
04-32 Position command 9 (pulse) -32767–32767 0
04-33 Position command 10 (rotation) -30000–30000 0
04-34 Position command 10 (pulse) -32767–32767 0
04-35 Position command 11 (rotation) -30000–30000 0
04-36 Position command 11 (pulse) -32767–32767 0

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Overload Capacity150% of rated current for 60 seconds
CommunicationDeviceNet
ProtectionOvervoltage, Undervoltage, Overcurrent, Overload, Overheat
Humidity5% to 95% (non-condensing)
CoolingForced air cooling
Control ModeV/F Control, Sensorless Vector Control