Chapter 12 Description of Parameter SettingsC2000
12.1-05-5
Accumulated Watt-hour for a Motor (W-hour)
Default: 0.0
Settings Read only
Accumulated Watt-hour for a Motor in Low Word (kW-hour)
Default: 0.0
Settings Read only
Accumulated Watt-hour for a Motor in High Word (MW-hour)
Default: 0
Settings Read only
Pr.05-28–05-30 records the amount of power consumed by the motors. The accumulation begins
when the drive is activated and the record is saved when the drive stops or turns OFF. The
amount of consumed watts continues to accumulate when the drive is activated again. To clear
the accumulation, set Pr. 00-02 as 5 to return the accumulation record to 0.
The accumulated total watts of the motor per hour = Pr. 05-30 x 1000000 + Pr. 05-29 x 1000 + Pr.
05-28 Wh
Example: When Pr. 05-30 = 76 MWh and Pr. 05-29 = 150 kWh, Pr. 05-28 = 400 Wh (or 0.4kWh),
the accumulated total kilowatts of the motor per hour = 76 x 1000000 + 150 x 1000 + 40 =
76150400Wh = 76150.4kWh

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Overload Capacity150% of rated current for 60 seconds
CommunicationDeviceNet
ProtectionOvervoltage, Undervoltage, Overcurrent, Overload, Overheat
Humidity5% to 95% (non-condensing)
CoolingForced air cooling
Control ModeV/F Control, Sensorless Vector Control

Related product manuals