Chapter 12 Description of Parameter SettingsC2000
12.2-00-26
12-2-4 IPM Adjustment
12-2-4-1 Pr.00-11=7 Interior PM FOC sensorless vector control (IPM sensorless)
1. Control Diagram
IPM sensorless FOC mode (applicable for C2000 V2.04 and above)
PM Sensorless FOC control is the control method dedicated for IPM, it uses the high salient
pole characteristic (Lq > Ld) of IPM to detect the positions of NS magnetic poles. By doing this,
it calculates the motor’s rotor position at low-speed frequency.