Chapter 9 Specification
ME300
9-3
9-2 230V Models
230V, one-phase
Frame A B A B A B
Model VFD_ _ _ ME21 _ _ _AA
0A8
1A6
2A8
ANN
ANS AFN
AFS ANN
ANS
AFN
AFS ANN
ANS
AFN
AFS
Applicable Motor Output (kW) 0.1 0.2 0.4
Applicable Motor Output (HP) 1/8 1/4 1/2
Output Rating
Heavy
duty
Rated Output Capacity (kVA) 0.3 0.6 1.1
Rated Output Current (A)
0.8
1.6
2.8
Carrier Frequency (kHz) 2–15
Normal
Duty
Rated Output Capacity (kVA) 0.4 0.7 1.2
Rated Output Current (A) 1.0 1.8 3.2
Carrier Frequency (kHz) 2–15
Input Rating
Rated Input
Current (A)
Heavy Duty 2.2 3.4 5.9
Normal Duty 2.8 3.8 6.7
Rated Voltage / Frequency One-phase AC 200240 V (-15– +10%), 50/60 Hz
Operating Voltage Range (V
AC
) 170265
Frequency Range (Hz) 4763
Weight (kg) 0.4 0.9 0.4 0.9 0.5 0.9
Cooling Method Convective cooling Fan cooling
EMC Filter
Optional
Built-in
Optional
Built-in
Optional
Built-in
Ingress Protection Rating IP20
Frame B C
Model VFD_ _ _ ME21 _ _ _AA
4A8 7A5 11A
ANN
ANS AFN
AFS ANN
ANS AFN
AFS ANN
ANS AFN
AFS
Applicable Motor Output (kW) 0.75 1.5 2.2
Applicable Motor Output (HP)
1
2
3
Output Rating
Heavy
duty
Rated Output Capacity (kVA) 1.8 2.9 4.2
Rated Output Current (A) 4.8 7.5 11
Carrier Frequency (kHz)
2–15
Normal
Duty
Rated Output Capacity (kVA) 1.9 3.2 4.8
Rated Output Current (A) 5 8.5 12.5
Carrier Frequency (kHz)
2–15
Input Rating
Rated Input
Current (A)
Heavy Duty 10.1 15.8 23.1
Normal Duty 10.5 17.9 26.3
Rated Voltage / Frequency One-phase AC 200240 V (-15– +10%), 50/60 Hz
Operating Voltage Range (V
AC
) 170265
Frequency Range (Hz)
4763
Weight (kg) 0.8 0.9 1 1.5 1 1.5
Cooling Method Convective cooling Fan cooling
EMC Filter Optional Built-in Optional Built-in Optional Built-in
Ingress Protection Rating IP20
Table 9-2
NOTE:
1. Default: heavy duty.
2. The value of the carrier frequency is set in the factory. To increase the carrier frequency, decrease the current. See the derating
curve diagram in Section 9-6 for more information.
3. When the load is a shock or impact load, use a higher level model.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ME300 Series and is the answer not in the manual?

Delta ME300 Series Specifications

General IconGeneral
Power Rating0.4 kW ~ 110 kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
CommunicationRS-485
Storage Temperature-20-60°C
DimensionsVaries by model
WeightVaries by model
Input Voltage3-phase 220VAC
Humidity90% RH, non-condensing

Related product manuals