Chapter 12 Description of Parameter Settings
ME300
12.1-00-12
If idling is allowed, or the load inertia is large, use “coast to stop. For example, blowers,
punching machines and pumps.
3. Motor stops by simple positioning: use with the functions for Pr.12-2012-35.
00-23
Motor direction control
Default: 0
Settings
0: Enable forward / reverse
1: Disable reverse
2: Disable forward
Enables the motor to run in the forward and reverse direction. You can use it to prevent a motor
from running in a direction that would cause injury or damage to the equipment, especially when
only one running direction is allowed for the motor load.
00-24
Digital operator (keypad) frequency command memory
Default: Read Only
Settings
Read only
If the keypad is the frequency command source, when Lv or Fault occurs, this parameter stores
the current frequency command.
00-25
User-Defined Characteristics
Default: 0
Settings bit 0–3: user-defined decimal places
0000b0000b: no decimal place
0001b0001b: one decimal place
0010b0010b: two decimal places
0011b0011b: three decimal places
bit 4–15: user-defined unit
000xh: Hz
001xh: rpm
002xh: %
003xh: kg
004xh: m/s
005xh: kW
006xh: HP
007xh: ppm
008xh: 1/m
009xh: kg/s
00Axh: kg/m
00Bxh: kg/h
00Cxh: lb/s
00Dxh: lb/m
00Exh: lb/h
00Fxh: ft/s