Chapter 12 Description of Parameter Settings
ME300
010xh: ft/m
011xh: m
012xh: ft
013xh: degC
014xh: degF
015xh: mbar
016xh: bar
017xh: Pa
018xh: kPa
019xh: mWG
01Axh: inWG
01Bxh: ftWG
01Cxh: psi
01Dxh: atm
01Exh: L/s
01Fxh: L/m
020xh: L/h
021xh: m3/s
022xh: m3/h
023xh: GPM
024xh: CFM
xxxxh: Hz
bit 0–3:
The displayed units for the control frequency F page and user-defined (Pr.00-04 = d10, PID
feedback), and the displayed number of decimal places for Pr.00-26 (support up to three
decimal places).
bit 4–15:
The displayed units for the control frequency F page, user-defined (Pr.00-04 = d10, PID feedback)
and Pr.00-26.
You must convert the setting value to decimal when using the keypad to set parameters.
Example: Assume that the user-defined unit is inWG and user-defined decimal place is the third
decimal point.
According to the information above, the corresponding unit to inWG is 01Axh (x is the set decimal