10EUT4TL 15EUG4TL 20EUG4TL 30EUT4TL
INPUT (DC)
Max. recommended
PV power
1)
13.2 kW
P
19 kW
P
25 kW
P
38 kW
P
Recommended PV
power range
8.8 ... 13.2 kW
P
14 ... 19 kW
P
18 ... 25 kW
P
26 ... 38 kW
P
Nominal power 10.5 kW 15.3 kW 20.4 kW 31 kW
Operating voltage 250 ... 1000 V
MPP voltage range @
nominal power,
balanced inputs
350 ... 850 V
DC
350 ... 800
V
DC
350 ... 800 V
DC
480 ... 800 V
DC
MPP voltage range
unbalanced inputs
350 ... 850 V
DC
470 ... 800 V
DC
480 ... 800 V
DC
620 ... 800 V
DC
Nominal voltage 635 V
DC
650 V
DC
Start up power 40 W
Absolute maximum
voltage
1000 V 1000 V 1000 V
Number of inputs 4 inputs (2 MPP trackers) 6 inputs (2 MPP
trackers)
Max. current 30 A (20 A x 2) 48 A (24 A x 2) 60 A (30 A x 2) 68 A (34 A x 2)
OUTPUT (AC)
Max. apparent power
2)
10.5 kVA 15.75 kVA 21.0 kVA 31.5 kVA
Nominal apparent
power
10.0 kVA 15.0 kVA 20.0 kVA 30.0 kVA
Voltage range
(3 phase)
3)
3 x 230 / 400 V (± 20 %) + N + PE (3 phases, 5 wires)
Nominal current 14.5 A 22 A 29 A 43 A
Max. current 16 A 25 A 32 A 46 A
Nominal frequency 50/60 Hz
Frequency range
3)
50 / 60 Hz ± 5 Hz
Power factor adjust-
able
0.80 Cap ... 0.80 Ind