40
Installation
IP65 protection class
IP55 protection class
Note:  15 and 20 TL pictured. 10 TL and 30 
TL may look slightly different.
Figure 5.1.:  SOLIVIA 10 TL, 15 TL, 20 TL, 30 TL protection classes
NOTE
The fans shown are without the required protective screen for illustrative 
purposes. The 15 TL, 20 TL and 30 TL models have 4 fans in the fan tray, 
whereas the 10 TL will only have one fan.
The upper section of the inverter, shown in the darker tone above, is sealed from the lower section 
and rated at IP65 enclosure protection. The lower section of the inverter, containing the cooling 
mechanisms, is rated at IP55 enclosure protection.
5.2  Mounting
This unit utilizes a wall mounting system. Please ensure the installation is perpendicular and 
with the AC plug at the bottom. Do not install the device on a slanted wall. The dimensions of the 
mounting bracket are shown in the following gures. There are 12 pcs. of M6 screws required for 
attaching the mounting plate to the wall. Attach the mounting plate securely to the wall, before 
attaching the inverter on the mounting plate.
NOTE
Please ensure you are using the correct fastener for the material you are 
attaching the inverter mounting plate to.