EasyManua.ls Logo

Delta SOLIVIA 10 EU T4 TL - Asymmetrical Loading for 10 TL, 15 TL, 20 TL, and 30 TL; Figure 6.9.: DC Wiring Illustration

Delta SOLIVIA 10 EU T4 TL
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
Wiring the Inverter
Maximum rating of input power:
Type of limit 10 TL 15 TL 20 TL 30 TL
Total input power 11 kW 16.5 kW 22 kW 30 kW
Input 1 & Input 2 7.3 kW 11 kW 14.7 kW 20.1 kW
Cable size:
Current rating Wire size
DC 34 A 5-6 mm
2
/ 10 AWG
DC wiring polarity is divided into positive and negative, which is shown in Figure 6-9. The connec-
tion should be consistent with the indicated polarity marked on the inverter.
Figure 6.9.: DC Wiring Illustration
6.3.1 Asymmetrical Loading for 10 TL, 15 TL, 20 TL, and 30 TL
The inverters operate using two separate MPP trackers that can handle both symmetrical and
asymmetrical loads to allow for optimum adjustment. This allows for the requirements of complex
PV system designs to be fullled. For example: east/west-facing roof (symmetrical load) or a
south facing roof such as a dormer (asymmetrical load).
See the following gures for explanation of how symmetrical and asymmetrical loading are
handled:

Table of Contents

Related product manuals