30
Connectible Devices Installation
Intercom System (for a/b)
The intercom systems “DoorLine
T01/02” and “DoorLine T03/04” of
the german Telekom’s division
T-Com can be connected via the
“DoorLine M06” to any a/b port. The
“Doorline” module provides the ac-
tor for the door opener contact.
Observe the following for connec-
tion and use of the intercom system:
The intercom system and the
“Doorline” module should be set
to their factory settings.
In the PBX Configuration:
Ports: a/b: Change menu in the
Configurator, select Doorline
under Type. Activate the Actua-
tor option, if you want to use the
actor port of the OpenCom 100
instead of the “DoorLine” relay.
The “DoorLine” actor can be op-
erated only when the speech
channel is open at the same
time. The internal actor can be
operated at any time.
The “Doorline” intercom system
has a number of bell keys to
which you can assign different
call numbers in the
PBX Configuration: Ports:
Doorline menu in the Configu-
rator.
You can call the “Doorline” inter-
com system by entering the
code procedure
*102.
The “Doorline” intercom system
can be connected to any a/b
port. However, you can use only
one “Doorline” with the
OpenCom 100.
For details on installing and config-
uring the “Doorline” intercom sys-
tem, refer to the product user guide.
The intercom system should be in-
stalled by qualified personnel only
as sensor/actor contacts will need to
be connected for this procedure.