User Manual DEV 1953
104 Copyright DEV Systemtechnik GmbH 2015-2017
5.7.4.5 Request Crosspoint Status (S?{Lvl})
This is the command for querying the switching status of the device or of a level
>@<sp> S?{Lvl}<CR>
The "{""}" are indicating the level information as optional.
As described in chapter 5.7.1 two scenarios are to be distinguished:
5.7.4.5.1 Individual Switching Mode with Individual Switch Level Assignment Enabled
(i) The response to the command requesting the switching status of the device
>@<sp> S?<CR>
initiates the device answer
S:00,<Src0> e.g. S:00,1
S:10,<Src1> S:10,0
(…) (…)
S:F0,<SrcF> S:F0,0
>_
with:
<Src0>…<SrcF> being either 0 for input port "In A" or 1 for input port "In B".
(ii) The response to the command requesting the switching status of a level
>@<sp> S?<Lvl><CR>
initiates the device answer
S:<Lvl>0,<Src> e.g. S:00,1
>_
with:
<Lvl> being the number (minus 1) of the addressed switch module and
<Src> being either 0 for input port "In A" or 1 for input port "In B".
5.7.4.5.2 Individual Switch Level Assignment Disabled
(i) The response to the command requesting the switching status of the device
>@<sp> S?<CR>
initiates the device answer
S:G
1
S
11
,<SrcG
1
S
11
> e.g. S:00,1
S:G
1
S
12
,<SrcG
1
S
12
> S:10,0
(…) (…)
S:G
x
S
xy
,<SrcG
x
S
xy
> S:(x-1)(y-1),1
>_
with:
G
1
…G
x
as the level parameter that indicates the group number (minus 1) of
groups with one or more members (assuming that there are "
x
"
groups);
S
11
…S
xy
as the destination parameter that indicates the single switch modules
within a group (assuming that there are "
y
" ("
y
" may vary!) switch
modules within a group);
<SrcG
1
S
11
>…<SrcG
x
S
xy
>
as the source information indicating the switching status of the related
switch module which is either 0 for input port "In A"
or 1 for input port "In B".