126 Copyright DEV Systemtechnik GmbH 2015-2017
5.9.4.3.9.16 .application.portTable.portEntry.poCardType
OID: .1.3.6.1.4.1.21035.41.2.9.1.16.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The DEV name for the module to which this port belongs to.
Examples: • "11-0014" for a DEV 11-0014 sensing switch module
• "PCF_ABSwitch" for a DEV 11-0031 switch module or
for "logical" switch modules (chapter 5.9.4.3.9)
5.9.4.3.9.17 .application.portTable.portEntry.poSlot
OID: .1.3.6.1.4.1.21035.41.2.9.1.17.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The slot location of the module to which the port belongs to.
Examples: • "Switch1" the switch module to which the port belongs to is
located in the first slot
• "Amp10" the distribution amplifier module to which the port
belongs to is located in the tenth slot
5.9.4.3.9.18 .application.portTable.portEntry.poRfSenseStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.18.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the RF level monitoring (or the digital signal quality
status), possible values:
"1" ok: the RF level is above the RF threshold level
(or the digital signal quality is "OK");
"2" not ok: the RF level is below the RF threshold level
(or the digital signal quality is "Fail");
"3" not applicable: is returned for ports without RF level
(or digital signal quality) information.
5.9.4.3.9.19 .application.portTable.portEntry.poBiasStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.19.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the LNB (bias) current monitoring.
For this type of device, "3" (notapplicable) is returned for all ports.
5.9.4.3.9.20 .application.portTable.portEntry.poLightStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.20.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The light detection status.
For this type of device, "3" (notapplicable) is returned for all ports.