C/43
- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
(g.91/C)
1
(g.90/C)
P
A
BOOM HEAD SOLENOID VALVE
(OPTIONAL)
(g.91/C Pos.”1”)
The switch is only installed in the presence of the boom head
solenoid valve (g.91/C Pos.”1”).
When using the solenoid valve it is possible to have divided
hydraulic controls on the boom head.
- Activate the push button (g.90/C Pos.”A”) to power the
solenoid valve, which will deviate oil ow. The indicator
light on the same switch indicates start-up.
The selector (g.90/C Pos.”A”) is used parallely to normal
service controls. First, choose the selector where oil ow
will deviate from, then carry out manoeuvres with the routine
service controls.
- ATTENTION:
Before starting any operations, verify function by means of
corresponding switches.