UTM-00339 | Rev 19
Page 186 of 253
DetNet South Africa Copyright © 2021
1. Main Menu
• Press SoftKey to select Prepare for Blast.
2. Prepare for Blast
• Press SoftKey to select Program Detonators.
3. Program Detonators
• Detonators will be programmed
• Press or button to return to Prepare for Blast Menu.
4. Prepare for Blast
• Press button to select Arm.
The following Remote Blast description details the manual process to arm the system.
The user is also provided with an option to Arm the Commander without the need to
connect the Tagger via an AutoArm function. The AutoArm function will allow the user to
scan a no-PIN yellow BlastCard and if there are no errors present; program and move to
the waiting for next press state. The user will then have to press next for 2 seconds and
the unit will then be ready to arm. The Commander (Bench and Base) should be mounted
on the supplied foot or a tripod for reliable RF connectivity.