UTM-00339 | Rev 19
Page 31 of 253
DetNet South Africa Copyright © 2021
Refer to Application document OPI-00390 for guidelines. The guideline does not supersede those required by the
local mine, explosives or statutory regulations/procedures/codes of practise regarding the use of DigiShot
®
Plus 4G
Detonators. In such cases, the MOST STRINGENT set of rules between the mine, explosives or local
regulations/procedures/codes of practise and the manufacturer must be followed.
Store DigiShot
®
Plus 4G Detonators in accordance with relevant regulatory/legal requirements.
Ensure no smoking or open flames near DigiShot
®
Plus 4G Detonators.
Always keep storage facilities clean and dry.
Ensure rotation of stock to use product with the specified shelf life.
Avoid dropping or applying any physical shock to DigiShot
®
Plus 4G Detonators because all detonators
are
impact sensitive.
The connector is splash proof; water inside the connector could cause leakage that could
result in
DigiShot
®
Plus 4G Detonators malfunctioning.
Keep detonators a minimum of 0.1m from cellular phones and 2m away from handheld radios while priming
and loading blastholes
Keep detonators a minimum of 2m from cellular phones and 2-way radios when preparing for blasting as
interference could cause
the 4G Detonator to malfunction.
Never attempt to open the DigiShot
®
Plus 4G Detonator as it could initiate.
Keep the connectors closed when not in use to prevent corrosion of the connector’s pins.
Grit and dirt inside the connector could damage the connector pins and result in poor connection
Explosives inside the connector may cause corrosion on the connector pins that could result in poor
connection and leakage.
Refer to the Electronic Detonator Material Data Sheet for detailed information on
Precautions for safe handling, Conditions for safe storage, Disposal methods and
Regulatory information.
4G DETONATORS MAY ONLY BE CONNECTED TO THE THE DIGISHOT
®
PLUS 4G COMMANDER IN
ACCORDANCE WITH LOCAL LEGISLATION AND PRESCRIBED BLASTING PRACTICES ON SITE WHICH MAY
REQUIRE THE BENCH TO BE CLEARED FOR BLASTING BEFORE CONNECTION TO A BLAST DEVICE IS
ALLOWED.