EasyManua.ls Logo

DigiTech RP-20 VALVE - Expression Pedal Assignments

DigiTech RP-20 VALVE
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting up an LFO
To set up an LFO that is linked to an effect parameter, the procedure is as follows:
1. Enter Assign Mode by pressing the <Assign> button.
2. Use the <Data> knob to scroll to the LFO page. The display looks something like:
3. You can press the <1> and turn the <Data> wheel to select which of the two LFOs you want to adjust.
4. Press the <2> button and turn the <Data> wheel to turn the LFO on or off.
5. Press the <3> button and turn the <Data> wheel to change the selected LFO's waveform. You can select SINe, TRIangle, SPecial1,
SPecial2.
6. Press the <4> button and turn the <Data> wheel to adjust the speed of the LFO cycle.
Any parameters assigned to the LFOs will now follow the modulating waveform of the LFO you selected.
Setting up a Dynamic Modifier
1. Enter assign Mode by pressing the <Assign> button.
2. Use the <Next Page> and <Previous Page> buttons to scroll to the first of two Dyn pages. The display looks something like:
3. You can press the <1> button and turn the <Data> wheel to select which of the two Dyns you want to adjust.
4. Press the <2> button and turn the <Data> wheel to turn the Dyn on or off.
5. Press the <3> button and turn the <Data> wheel to set the threshold above which dynamic modification of the parameter begins.
Dyn LoThrs HiThrs
2
FACTORY USER
%kHz
msdB
1
1
CHANGEDLINK
%kHz
msdB
Off
2
CHANGEDLINK
%kHz
msdB
0
3
CHANGEDLINK
0
4
CHANGEDLINK
PAGE
18
OF
19
COMP WAH TUBE EQ
L/R OUTS
L/R OUTS
#
b
GATE
BANK
LFO WvForm Speed
2
FACTORY USER
%kHz
msdB
1
1
CHANGEDLINK
%kHz
msdB
Off
2
CHANGEDLINK
%kHz
msdB
Sin
3
CHANGEDLINK
Hz
006
4
CHANGEDLINK
PAGE
17
OF
19
COMP WAH TUBE EQ
L/R OUTS
L/R OUTS
#
b
GATE
BANK
RP-20 Valve
User Guide
Section - 5 Advanced Topics
53

Table of Contents

Related product manuals