C16x/C24x/C30x Operator’s Manual Service - 87
Each Use
Check Air Filter Elements
C16x
Check air filter element before each use. Replace
element if it is dirty or damaged.
1. Remove wing nuts and cover.
2. Remove filter element, do a visual check and
replace if dirty.
C24x and C30x
Press dust ejector valve to release dust every
10 hours.
NOTICE: Cleaning can damage the filter
elements.
• Do not tap filter elements to loosen dirt.
• Do not use compressed air or water.
• Replace the elements.