STEP FOUR INSPECT BALL DETENT ARM
CLEAN AND INSPECT THE BALL DETENT ARM in the ball
detent assembly. It should move freely when pressed in
and released. If the plunger or the Quick-Strip latch tension
spring show significant signs of wear or binding, replace
them following the instructions in ADVANCED MAINTENANCE 6.3.
STEP FIVE REINSTALL DETENT
REINSERT THE BALL DETENT ASSEMBLY by hooking its
pointed edge into the front side of its pocket in the Luxe®
body. Then angle the rear into place, allowing the rare-earth
magnets to grip and secure it in place. Make sure that the
latch has clicked into the locked position. Test the latch by
pressing on the forward point of the detent assembly to
make sure it does not pop out.
STEP THREE
CLEAN VISION™ EYE POCKET
LIFT OUT THE VISION™ EYE from its pocket in the Luxe
®
body. Using a soft cloth or cotton swab, clean any paint,
debris or grease from the passage between the eye pocket
and the breech, or from the eye itself. If debris buildup
is severe, use a cotton swab dampened with rubbing
alcohol for cleaning the Vision™ eye and its pocket and
allow them to dry completely before proceeding. Take
care not to scratch the Vision™ eye or strain its flex-strip
circuit. Gently re-seat the Vision™ eye in its pocket, with its
emitter or sensor facing inward.
3 4 5