ADVANCED MAINTENANCE 6.5
VISION AND SOLENOID VALVE REMOVAL
WITH THE RECEIVER AND GRIP FRAME APART (see MAINTENANCE 3.4), the solenoid valve manifold may be
removed from the Luxe
®
by taking out the mount screw at its front with a 1/16-inch allen wrench [FIG. 1]
Further disassembly of the solenoid valve from its manifold is achieved by removing two screws [FIG. 2]
Note- The Luxe
®
X solenoid is not user-servicable and should not be disassembled.
On reassembly, inspect exposed o-rings and replace if necessary. A very thin film of GR33SE
may be used
as an assembly lubricant to help the o-rings slide smoothly into their pockets and stay in place while the
parts are being handled. Take caution not to leave free gobs of lubricant in or around the o-rings and air
passages, as they can gum up the solenoid valve and prevent smooth operation.
The Vision
emitter and detector may be removed by first lifting out the detent assemblies (see MAINTENANCE 5.2)
then unscrewing the upper Vision
contact strip screw from the bottom of the body [FIG. 3] and lifting out
the Vision
flex circuit.