OPERATION
L025317 Issue 1 March 2011 3-41
D320i
Default parameters
Parameter ranges
Parameter Laser System
D320 i-Tech 8mm Scan head
StepPeriod [μs] 30
JumpDelay [μs] 100
MarkDelay [μs] 100
PolygonDelay [μs] 20
LaserOffDelay [μs] 110
LaserOnDelay [μs] 80
MaxVectorLength [mm] 0.25
LaserPower [%] 95
JumpSpeed [bit/ms] 7000
MarkSpeed [bit/ms] 6000
Parameter Laser System
D320 i-Tech 8mm Scan head
StepPeriod [μs] 10..100
JumpDelay [μs] 0..500
MarkDelay [μs] 0..500
PolygonDelay [μs] 0..500
LaserOffDelay [
μs] 10..500
LaserOnDelay [μs] 10..500
MaxVectorLength [mm] 0..100
JumpSpeed [bit/ms] 100..16000
MarkSpeed [bit/ms] 100..16000