MAINTENANCE AND FAULT FINDING
5-26 L025317 Issue 1 March 2011
Changing Filter Bags
WARNINGS: (1) Full protective clothing must be worn and
correct disposal methods used immediately.
(2) Filters must be changed in accordance with the
instruction sheet provided with the filter kit.
Note: Filter alerts may be caused by debris build up in the extraction nozzle,
hose, air inlet or sense line in the air inlet. Always check these areas are
free from debris before changing the filter.
The filter bag is situated in the bottom compartment.
(1) Turn off the extractor.
(2) Turn the two door latches on the front of the machine 90°, then open
the cabinet door.
(3) Using the filter change kit provided with each new filter, pull the Filter
Bag off the air inlet, ensuring the bag inlet faces away from the operator,
and remove.
(4) Bag and seal the old filter in the bag provided.
(5) Insert the new Filter Bag, pushing the entry hole in the filter over the
air inlet. Ensure that the filter entry is fully pushed onto the inlet pipe.
(6) Close the cabinet door, turning the latches fully in their respective
directions.
(7)
For DPX2000 only
- Replace the chemical pad that is supplied with
the Super Filter bag.
Changing Main Filter
WARNINGS: (1) Full protective clothing must be worn and
correct disposal methods used immediately.
(2) Filters must be changed in accordance with the
instruction sheet provided with the filter kit.
(1) Turn off the extractor.
(2) Open the cabinet door.
(3) Turn the filter locking handle 180° counter clockwise, so that it is
horizontal and in the filter unlocked position.
WARNING: This filter is heavy and must be removed with
care.
(4) The filter will drop slightly to allow release. Pull the main filter forward
and remove completely.
(5) Bag and seal the old filter in the bag provided.