INSTALLATION INSTRUCTIONS
2-18 EPT031055 Issue 2 September 2017
The product detect interface offers NPN or PNP standard wiring. Different
types of product detect sensors (optical, magnetic, etc.) can be connected
to this input. A shaft encoder may be connected here.
Connector Type: IEC 60130-9 Type 08 way female
Mating Cable Connector (IP67 Types):
Lumberg: 033208-1
Pin description
Pin 1 +24VF - 24V floating, max 120mA
Pin 2 GNDF - Floating Ground
Pin 3 PD+ - Product Detect positive input
Pin 4 PD- - Product Detect negative input
Pin 5 CHA+- Encoder Channel A positive input
Pin 6 CHA- - Encoder Channel A negative input
Pin 7 CHB+ - Encoder Channel B positive input
Pin 8 CHB- - Encoder Channel B negative input
All input circuits contain opto couplers.
The input range is 10-30V, (NPN, PNP, RS422 differential) at an input
impedance of 2 kOhm.
The maximum pulse frequency of CHA and CHB is 120 kHz
The minimum pulse length of the PD input is 10 micro seconds.
The maximum current for X3 and X6 and X7 and X21 (optional user port) is
0.5A. In case of an over-current an automatic resettable fuse protects the
system.