4. Regular inspection
67
Electric system
Battery
Check for the electrolyte leakage by crack in the
b
attery, and replace the battery if defective.
Check the amount of electrolyte, and replenish distill
ed
w
ater if insufficient.
Check the specific gravity of electrolyte. If it is bel
ow
t
he specified value (1.12 ~ 1.28), replenish it.
DV2213040A_E
Starter
When servicing the engine, immerse the starter motor’s
pinion gear and ring gear in the fuel, wash them
completely, and apply grease again. When you clean the
surrounding of engine, be careful so that water may not
enter the starter.
Viewing the
gravity meter
Liquid level
indicating line
liquid level upper limit
liquid level lower limit
lsotator
UPPER LEVEL
LOWER LEVEL
CAUTION
Starter should be protected from humidity all the
tim
e.
Before working on the electric system, be sure to
disconnect the ground wire (“-” minus wire) of
the battery. Short circuit may occur while working
on the electrical system. Connect the ground wire
last after completing all of work.