4. Regular Inspections
46
Electrical System
Battery
1. Check the battery for electrolyte leakage due to cracks. If
it is cracked, replace it with a new one.
2. Check the electrolyte level and add distilled water as
necessary.
3. Measure the specific gravity of the electrolyte. If the
measurement is below the specified range (1.12 ~ 1.28),
add more.
EFM1007I
How to use a hydrometer Level indicator line
Upper limit line
Lower limit line
Separator
- Upper limit line
- Lower limit line