EasyManua.ls Logo

Dover OPW SiteSentinel iSite - 4.4 Model 7100 V Flex Probe

Dover OPW SiteSentinel iSite
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 36 of 145
www.opwglobal.com
4.4
Model 7100V Flex Probe
The 7100V Flex Probe (Figure 4-3) utilizes the same magnetostrictive
technology for above ground tanks up to 50 feet (15.2 m) in height. It is
important to follow the handling instructions to avoid damaging the probe
and voiding the warranty. During the unpacking and installation of the
Model 7100V Flex Probe, always keep the diameter of the coils between
40 and 48 inches (about 1 m).
Flex Probe Installation Requirement:
Flex probe head/wiring must be installed in weatherproof junction box
with seal packs for wiring connections. Failure to comply with these
requirements may invalidate probe warranty.
Figure 4-3 Model 7100V Flex Probe
Model 7100V Flex Probe
Input Voltage:
23 - 28 VDC
Sensor Length:
Flexible Kynar®: R1 & T1: (44”- 600”/111.8-
1,524 cm); R5: (51”- 600”/129.5-1,524 cm)
Enclosure Material:
Kynar®
Rating:
IP68
Resolution:
0.010” (0.25 mm) Inventory Mode
Linearity:
+/- 0.01% of Full Scale
+/- 0.010” (0.25 mm), whichever is greater
Repeatability:
+/- 0.001% of Full Scale
+/- 0.00025” (0.64 mm), whichever is greater
Temp. Accuracy:
Absolute +/- 2°F (+/- 1°C)
Temp. Measurement:
Up to five (5) along the sensor span;
Resolution: +/- 0.01°F (+/- 0.01°C)
Temp. Sensing Range:
-40°F to +158°F (-40°C to +7C)
Operating Temp. Range:
-40°F to +158°F (-40°C to +7C)
Environment:
NEMA 4
Floats (not included):
Specs based on 4” (10.2 cm) standard floats
Listings:
UL; Intrinsically Safe
I.S. Barrier
24V Part Number 20-4345
Multi-Drop Capability
Requires one I.S. Barrier channel per probe

Table of Contents

Related product manuals