EasyManua.ls Logo

Dover OPW SiteSentinel iSite - 5.18 Density Measurement Sensor (DMS)

Dover OPW SiteSentinel iSite
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 58 of 145
www.opwglobal.com
5.18
Density Measurement Sensor (DMS)
Part No. 30-3232
The Density Measurement Sensor (DMS) (Figure 5-20) installs on the
pre-existing probe and continuously measures the average density of
the fuel in the tank. This provides a measure of even the smallest
change in product density within the API density range. Fuel-density
reports can be displayed real-time on the console or exported to an
external device. The readings can be either nominal or temperature-
corrected density.
Density Measurement Sensor
Materials:
Nitrophyl, Delrin, and Stainless-Steel spring
Resolution:
0.00004 g/cc
Accuracy:
+/- 0.0025 g/cc
Density Range:
0.6 1.0 g/cc
Operating Temperature:
-40°F to 158°F (-40°C to +70°C)
Dimensions:
Length: 11” (27.9 cm), Diameter: 2” (5.1 cm)
Sensors per Barrier:
16 maximum
Suggested Location:
6” (15.2 cm) from bottom of probe)
Note:
Use set screw at top and bottom of
sensor to hold in position
Figure 5-20 Density Measurement Sensor

Table of Contents