4 Dräger Polytron 8100
6 Maintenance...........................................................28
6.1 Maintenance intervals..............................................28
6.1.1 During commissioning .............................................28
6.1.2 Every 6 months........................................................28
6.1.3 Change sensor on demand .....................................28
6.2 Calibration ............................................................... 28
6.2.1 Zero Calibration ....................................................... 29
6.2.2 Span calibration.......................................................29
6.2.3 Auto Calibration ....................................................... 30
6.3 Troubleshooting....................................................... 31
6.3.1 Fault reference ........................................................31
6.3.2 Warning reference ...................................................32
6.4 Replacing the sensor...............................................33
6.5 Replacing the main electronics................................33
7 Factory default settings ........................................ 34
7.1 Settings which can be changed via the menu ......... 34
7.2 Fixed settings ..........................................................35
8 Sensor principle ....................................................36
9 Disposing the instrument .....................................36
10 Technical data........................................................37
10.1 Approvals................................................................. 37
10.1.1 ATEX, IECEx, UL, CSA ...........................................37
10.1.2 DIN EN 50104 for DrägerSensor O2 (6809720)...... 37
10.1.3 DIN EN 50104 for DrägerSensor O2LS (6809630) . 39
10.2 Marking....................................................................41
10.3 Signal transmission to central controller..................41
10.3.1 Analog signal ...........................................................41
10.3.2 HART digital communication ...................................41
10.4 Power supply and relays .........................................41
10.5 Physical specifications............................................. 41
10.6 Environmental parameters ......................................41
10.7 Environmental influences ........................................41
10.8 Tightening torque for instrument threads.................42
10.9 Tightening torque and size for field wiring terminals 42
11 Declaration of Conformity.....................................43
12 Control Drawing.....................................................44

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Polytron 8100 and is the answer not in the manual?

Dräger Polytron 8100 Specifications

General IconGeneral
DisplayLCD with backlight
Sensor TechnologyElectrochemical, Infrared, Catalytic Bead
Output Signal4 to 20 mA, HART
Ingress ProtectionIP66
Housing MaterialStainless steel or Aluminum
Gas TypesCombustible gases, toxic gases, oxygen
ApprovalsATEX, IECEx
CommunicationHART
Measurement RangeDepends on sensor type
CertificationsCE
Power Supply12-30 V DC