5.3 Programming Descriptions
[378] Test Transmission Time of Day
The panel can be configured to communicate a test transmission signal to the monitoring station. Program 4 digits – [HHMM] using
military standard. For a test transmission at 11:00 pm, program data [2300]. Valid entries are [0000] to [2359], [9999] to disable.
[380] First Communicator Options
[9] Delinquency Transmission Delay: Number of hours (Activity Delinquency) or days (Arming Delinquency) the panel delays
before transmitting the event to the central station. Whether this value is in hours or days is determined if Delinquency is for
Activity (Hours) or Closing (Days) as specified in Section [380] Option 8. The timer starts under the following conditions:
1. When the system is armed in Stay Mode;
2. When the system is disarmed;
3. When a zone is violated and restored while system is disarmed or stay armed (Interior, Interior Delay, Interior Stay/
Away, Delay Stay/Away, Interior Delay or Night zones only.
The activity delinquency timer will be ignored when the system is armed in away mode. Zones that are bypassed in [*][1]
will not reset the timer. Automatic restore conditions or activity from fire or CO zones should not reset this counter. If the sys-
tem is programmed to monitor Closing Delinquency, the timer will be programmed in days. The timer will restart every time
the system is disarmed. Valid entries: [001] to [255].
[10]
For Future Use
Option Description
[1]
Communications
ON: Communications Enabled. The system communicator is enabled and all events with reporting codes will
be reported to the monitoring station.
OFF: Communications Disabled. The communicator is disabled and events will not be transmitted to the moni-
toring station. Downloading may still be performed if enabled.
[2]
Restore
Transmission
ON: Restores Transmissions on Bell Time-out. Zone restore reporting codes will not be transmitted until the zone
has been restored, the bell cut-off time has expired, and the zone is not in swinger shutdown. If the zone is not
restored when the bell cut-off time expires, the restore will be transmitted when the zone physically restores or when
the system is disarmed.
Note: 24 Hr Zones will not restore until physically restored.
OFF: Restore Transmissions Follow Zones. Zone restore reporting codes will be transmitted when the zone is
physically restored and the zone is not in swinger shutdown. If the zones are still violated when the system is dis-
armed, the restore codes will be transmitted when the system is disarmed.
[3]
Dialing Method
ON: Pulse Dialing Enabled. The panel uses rotary (pulse) dialing.
OFF: DTMF Dialing. The panel uses touchtone (DTMF) dialing.
[4]
Pulse Dialing
Options
ON: Switch to Pulse Dialing after 4 DTMF Attempts. If DTMF dialing is enabled, the control panel dials tele-
phone numbers using DTMF dialing for the first 4 attempts. If unsuccessful, the control panel switches to pulse
(rotary) dialing for the remaining attempts.
OFF: DTMF Dial for all Attempts. If DTMF dialing is enabled, the control panel dials telephone numbers using
DTMF dialing for all dialing attempts.
[5] Future Use
[6] ON: Alternate Dialing Enabled. The communicator switches to the next backup phone number in the sequence
after each failed dialling attempt. This continues until communications are successful, or the sequence has been
repeated 5 times.
OFF: Call Primary Number, Backup to Secondary. If 5 attempts to communicate to the primary telephone number
fail, the communicator switches to the next backup and makes up to 5 more attempts. If the communication failure con-
dition persists, the communicator will attempt the second and third backup phone numbers if programmed.
[7] Future Use
[8]
Delinquency
ON: Delinquency Follows Zone Activity (Hours). The Delinquency feature follows zone activity—if there is no zone
activity on the system, the delinquency transmission delay counter in Section [377] begins counting in hours. When the
counter reaches the programmed value, the panel communicates the delinquency code to the central station.
Note: This code will not be transmitted for partitions that are “Away” armed. Activity on bypassed zones does not
affect this timer. The timer is reset on arming.
OFF: Delinquency Follows Arming (Days). The Delinquency feature follows arming—if a partition has not
been armed for a programmed number of days, the panel communicates the delinquency code. This feature may
be disabled by entering 000 in Section [377].