24
Alarm Reporting Codes, Inputs 1-12
[062] Fire On Time
Default: 05
The Bell Pulse On Time is used with Digital Input#1 when configured for Bell Follower mode.
The Bell Pulse On/Off Time is the time of the pulse width. This option is programmed in hex
times 100 milliseconds.
[063] Fire Off Time
Default: 05
The Bell Steady On Time is used with Digital Input #1 when configured for Bell Follower
mode. This is the minimum time in 100ms increments that the bell must be active/sounding
before it will be considered a steady on state and generate the Burglary Alarms. This option is
programmed in hex times 100 milliseconds.
[064] Restoral Delay Time
Default: 64
The Restoral Delay Time is used with Digital Input#1 when configured for Bell Follower
mode. It is the minimum time that the bell must be inactive before it will be considered a Fire/
Burglary Restoral.
[065] Fire Pulse Count
Default: 03
The Fire Pulse Count is used with Digital Input #1 when configured for Bell Follower mode.
The pulsed count will be the minimum number of pulses (high and low forming 1 cycle) before
the T-Link will consider it an alarm state.
[066] SIA ACK Time
Default: 02
The SIA ACK Time option is the maximum wait time (seconds) for a response from a receiver
for any messages sent to the receiver.
[067] DVACS Account Number
Default: 00
The DVACS Account Number. The T-Link will use this number to receive DVACS signals
from the control panel and to supervise the panel.
[068] DVACS Extended
Default: 01
The SG-DV1660LC software versions 3.00 and higher support the group arm/disarm option. If
a value other than ‘00’ is programmed here, the T-Link TL250 will poll the subscribers control
unit repeatedly to get the transmitter group number arm/disarm status change and the user num-
ber. This information is combined then sent to the receiver. This allows the automation soft-
ware to keep track of partition arm/disarm status. Program ‘01’ to enable or ‘00’ to disable this
option.
Default: Default:
FF
|______|______|
Input 1 Alarm
FF
|______|______|
Input 7 Alarm
FF
|______|______|
Input 2 Alarm
FF
|______|______|
Input 8 Alarm
FF
|______|______|
Input 3 Alarm
FF
|______|______|
Input 9 Alarm
FF
|______|______|
Input 4 Alarm
FF
|______|______|
Input 10 Alarm
FF
|______|______|
Input 5 Alarm
FF
|______|______|
Input 11 Alarm
FF
|______|______|
Input 6 Alarm
FF
|______|______|
Input 12 Alarm