INSTALLATION
SECURITY ACCOUNT
FIND IT
Installer Code Access
Master Code Access
Setting
Default
Description
Entry/Exit delays limits
Disabled
When enabled, the range for entry and exit delays is as follows:!
-Entry delay: 30-240 seconds,Exit Delay: 45-254 seconds!
When disabled, the range for entry and exit delays are as follows:!
-Entry delay: 5 to 240 seconds, Exit delay: 5 to 254 seconds!
Note: for UL/cUL set entry delay to 45 sec. and for UL set exit delay to max 120 sec. and
for cUL set exit delay to 60 sec.
Weather Temperature
F
Select the temperature format. (Fahrenheit or Celsius)
Languages
English
Select a panel language. All settings and menus will change except
videos. (English, French and Spanish)
Favourite Languages
English/
Spanish
Select your favourite languages. This setting determines what 2
languages the bi-lingual toggle uses in the Apps section. Favourite 1
is the primary language on the panel, favourite 2 is the secondary
language. (English, French and Spanish)
IQ2 Panel
Enabled
Enable or Disable the ability to pair an IQ2 secondary panel.
Jam Detection*
Disabled
When enabled the system can detect when an unusual amount of
RF signals are being transmitted leading to a potential panel
malfunction. This will report to the central station and handled
accordingly.
Jam Detection Local Alarm*
Disabled
When enabled the system will sound a local alarm. “Jam Detection
must be active for this to function properly.