EasyManua.ls Logo

DSC Touch-SCW9067

DSC Touch-SCW9067
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
SECURITY ACCOUNT
FIND IT
Settings
Installation
Security
Account
Setting
Default
Description
Account Number
blank
Security provider account number (up to 10 characters)
Power Management
Enabled
An energy-saving function when running on battery power only
Power Management Sleep
Timeout
1
Panel initiates power management mode a specified number of
minutes after last touch
Power Restoration
Disabled
Turn on or off sensor hold for 60 seconds during power!
restoration.
Loss of Supervisory Signals
for Emergency Sensors
4
Select the length in hours (4) before reporting a loss of!
supervision on life safety devices.
Loss of Supervisory Signals
for Non Emergency Sensors
24
Select the length in hours (24) before reporting a loss of!
supervision on security devices
Loss of AC Power Timeout
3
Select the length in minutes (1-10) before reporting an AC power
loss.
Loss of Cell Signal Timeout
30
Select the length in minutes (10-120) before reporting a loss in
cellular signal.
Installer Code Access
Master Code Access
DSC Confidential and Proprietary Page of 20 114
© Last updated 4/29/15 All rights reserved
Note: For UL/cUL, the wireless supervision window for Emergency sensors (Smoke detectors, CO detectors) shall be set to 4h.