39
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HYDRAULIC SCREW COMPRESSORS
OPERATION
5. OPERATION
5.1. BEFORE STARTING THE COMPRESSOR
ATTENTION!
Before starting the compressor first time, make sure that the unit is filled
with oil.
The compressor is delivered with compressor oil. Only in special cases compressor
is delivered without compressor oil.
The oil level must be between min and max.
MAX
MIN
Picture 33: Oil level of the HKR compressor
NOTE!
Check the compressor oil fill periodically
ATTENTION!
Never remove the oil filler cap when the compressor is running!
WARNING
RISK OF BURNS!
Parts of the unit, oil, and oil filler cap
can be hotter than 80 °C!
Wear personal safety equipment!

Table of Contents