The Eaton 9A is designed for reliable, autonomous operaon while providing you with no-
caons and alerts whenever a potenal operaonal or performance issues occur.
Usually, the alarms shown by the product do not mean that the output power is aected.
Instead, they are prevenve alarms intended to alert the user.
• Some alarms may be announced by a beep every 0.5 seconds. Example = "Baery low".
• Faults are announced by a connuous beep and LCD background transfer to red color.
Use the following troubleshoong chart to determine the UPS alarm condion.
7.1 Typical alarms and faults
If the UPS system does not operate correctly, check the operang status on the LCD display.
Alarms String Fault String
Site fail SITE Inverter short SHOR
Fan fail FANF Overload fault OVLD
Baery over voltage (over charged) HIGH Inverter so start fail ISFT
Baery low bLOW Bus so start fail bSFT
Charge fail CHGF Over temperature fault OVTP
Inverter temperautre high TEPH Inverter voltage low INVL
Ambient temperature high AMbH Inverter voltage high INVH
Baery open bOPN Bus voItage over bUSH
Overload OVLD Bus voItage low bUSL
EPO EPO Bus voItage unbalance bUSE
Baery fault bATF Bus short bUSS
NTC open NTCO
If the UPS system does not operate correctly, please aempt to solve the problem using
the table below.
Condions Possible cause Acon
No indicaon, no warning tone
even though system is connected
to mains power supply.
No input voltage.
Check building wiring socket outlet and input
cable.
Display Mode string ”STbY” in
LCD, even though the power
supply is available.
Inverter not switched on. Press “On” Switch.
Display Mode string ”bATT” in
LCD, and audible alarm sounding
every 1 beep in every 4 seconds.
Mains power supply has
failed, or Input power
and/or frequency are out
of tolerance.
Switching to baery mode automacally.
Check input power source and inform dealer if
necessary.