6. Function blocks
6.1 Manufacturer function blocks
decimal binary
I1 13 219 0000 0000 0000 0000 0011 0011 1010 0011
I2 57 193 0000 0000 0000 0000 1101 1111 0110 1001
QV 60 618 0000 0000 0000 0000 1110 1100 1100 1010
Example NOT I1 = QV
decimal binary
I1 13 219 0000 0000 0000 0000 0011 0011 1010 0011
I2
QV -13 220 1111 1111 1111 1111 1100 1100 0101 1100
See also
Section "AL - Alarm function block", page 349
Section "D - Text display", page 357
Section "D - Text display editor", page 366
Section "DL - Data logger", page 380
Section "JC - Conditional jump", page 386
Section "LB - Jump label", page 391
Section "MR - Master reset", page 393
Section "NC - Numerical converter", page 397
Section "BV - Boolean operation", page 353
356
easyE4 11/18 MN050009 EN www.eaton.com