M-Max Series adjustable frequency drive
MN04020002E
For more information visit: www.eaton.com 37
February 2010
Table 11: All Parameters (continued)
PNU ID
Access
Right
RUN Designation Value Range
Factory
Setting
User
Setting
Drives Control
P6.1 125 Remote control
place
1 = Control signal terminals (I/O)
2 = Control unit (KEYPAD)
3 = Field bus (BUS)
1
P6.2 117 Remote
reference
0 = Fixed frequency (FF0)
1 = Keypad (REF)
2 = Field bus (BUS)
3 = AI1 (analog set point 1)
4 = AI2 (analog set point 2)
5 = Motor potentiometer
1
P6.3 101 Min. frequency 0.00 – P6.4 Hz 0.00
P6.4 102 Max. frequency 6.3 – 320.00 Hz 60
P6.5 103 Acceleration
time (acc1)
0.1 – 3000s 3.0
P6.6 104 Deceleration
time (dec1)
0.1 – 3000s 3.0
P6.7 505 Start function 0 = Acceleration time (ramp)
1 = Flying restart
0
P6.8 506 Stop function 0 = Fee coasting
1 = Deceleration time (ramp)
0
P6.9 500 S ramp,
temporal S form
0.00 = Linear
0.1 – 10.0s (S-shaped)
0.0
P6.10 717
Automatic restart
(REAF), wait time,
(P6.13 = 1)
0.10 – 10.00s 0.50
P6.11 718 Automatic restart
(REAF), test time,
(
P6.13 = 1)
0.00 – 60.00s 30.00
P6.12 719 Automatic restart
(REAF), start
function
0 = Acceleration time (ramp)
1 = Flying restart circuit
2 = according to P6.7
0
P6.13 731 Automatic restart 0 = Inhibited
1 = Enabled
0
P6.14 1600 Stop on direction
reversal
0 = No
1 = Yes
1
P6.15 184 Keypad reference,
operating unit
0.00 – P6.4 Hz 0
P6.16 1474 Stop button
active
0 = No
1 = Yes
1
P6.17 1427 Remote control
place [2]
1 = Control signal terminals (I/0)
2 = Control unit (KEYPAD)
3 = Field bus (BUS)
3
P6.18 1428 Remote
reference [2]
0 = Fixed frequency (FF0)
1 = Operating unit (REF)
2 = Field bus (BUS)
3 = AI1 (analog set point 1)
4 = AI2 (analog set point 2)
5 = Motor potentiometer
2