M-Max Series adjustable frequency drive
38 For more information visit: www.eaton.com
MN04020002E
February 2010
Table 11: All Parameters (continued)
PNU ID
Access
Right
RUN Designation Value Range
Factory
Setting
User
Setting
Drives Control (continued)
P6.19 502 — Acceleration
time (acc2)
0.1 – 3000s 10.0
P6.20 503 — Deceleration
time (dec2)
0.1 – 3000s 10.0
P6.21 526 — Transition
frequency
(acc1 – acc2)
0.00 – P6.4 Hz 0.00
P6.22 1334 — Transition
frequency
(dec1 – dec2)
0.00 – P6.4 Hz 0.00
P6.23 1429 — REV inhibited 0 = No
1 = Yes
0
P6.24 509 — Skip frequency 1,
lower value
0.00 – P6.4 Hz 0.00
P6.25 510 — Skip frequency 1,
upper value
0.00 – P6.4 Hz 0.00
P6.26 511 — Skip frequency 2,
lower value
0.00 – P6.4 Hz 0.00
P6.27 731 — Skip frequency 2,
upper value
0.00 – P6.4 Hz 0.00
P6.28 513 — Skip frequency 3,
lower value
0.00 – P6.4 Hz 0.00
P6.29 514 — Skip frequency 3,
upper value
0.00 – P6.4 Hz 0.00
P6.30 759 — Automatic
restart, number
1 – 10 3
P6.31 1481 — Hand mode
control place
1 – 3 1
P6.32 1482 — Hand mode
reference
0 – 5 3
P6.33 1483 — Hand mode
keypad lock
0 – 1 1
Motor
P7.1 113 — Motor, rated
current
0.2 x I
e
... 2 x I
e
( Motor rating plate)
I
e
P7.2 107 — Current limit 0.2 x I
e
... 2 x I
e
1.5 x I
e
P7.3 112 — Motor, rated
speed
300 – 20,000 rpm
( Motor rating plate)
1720
P7.4 120 — Motor, power
factor (cos )
0.30 – 1.00
( Motor rating plate)
0.85
P7.5 110 — Motor, rated
operating
voltage
180 – 500V
( Motor rating plate)
230
480
P7.6 111 — Motor, rated
frequency
30 – 320 Hz
( Motor rating plate)
60 Hz