POWERXL SERIES VFDS MN040060EN—September 2020 www.eaton.com
Heat loss data
Table 32. Losses, cooling requirements, and audible noise.
Output Rating Control only Max rating Airflow Noise
Input voltage
Frame
size
Drive catalog
number
CT/I
H
current
amps
VT/I
L
current
amps
Fans on
watts
Fans off
watts
CT/IH
watts
VT/IL
watts CFM (m3/h) dBA
100 Vac to 120 Vac
50/60 Hz
1-phase
FR1 DM1-111D6 1.6 2.5 12 8 22 33 14.83 (25.2) 56.9
DM1-113D0 3 4.8 12 8 48.5 81.1 14.83 (25.2) 56.9
FR2 DM1-114D8 4.8 6.9 16.5 10.1 51 73 24.72 (42) 55.6
DM1-116D9… 6.9 7.8 16.5 10.1 73 84 24.72 (42) 55.6
200 Vac to 240 Vac
50/60 Hz
1-phase
FR1 DM1-121D6 1.6 2.5 13 9 22 31 14.83 (25.2) 56.9
DM1-123D0 3 4.8 13 9 34 56 14.83 (25.2) 56.9
DM1-124D8… 4.8 7.8 13 9 53 93 14.83 (25.2) 56.9
FR2 DM1-127D8 7.8 11 22 11 79 113 37.4 3 (63.6) 65.6
DM1-12011… 11 17.5 22 11 116 201 37.4 3 (63.6) 65.6
FR3 DM1-12 017… 17.5 25.3 24 12 163 254 42.37 (72) 58.7
200 Vac to 240 Vac
50/60 Hz
3-phase
FR1 DM1-321D6 1.6 2.5 12 8 22 33 14.83 (25.2) 56.9
DM1-323D0… 3 4.8 12 8 37.6 46.4 14.83 (25.2) 56.9
DM1-324D8… 4.8 7.8 12 8 42 85 14.83 (25.2) 56.9
DM1-327D8… 7.8 11 12 8 75 99 14.83 (25.2) 56.9
FR2 DM1-32011 11 17.5 16.5 10.1 93 159 24.72 (42) 55.6
DM1-32017 17.5 25.3 16.5 10.1 140.3 242.7 24.72 (42) 55.6
FR3 DM1-32025 25.3 32.2 19.5 10.4 237.4 332.3 42.37 (72) 58.7
FR4 DM1-32032… 32.2 48.3 43 11.7 260.7 432.4 75.56 (128.4) 65.9
DM1-32048… 48.3 62.1 43 11.7 445.4 618.2 75.56 (128.4) 65.9
380 Vac to 480 Vac
50/60 Hz
3-phase
FR1 DM1-341D5… 1.5 2.2 13 9 37 43 14.83 (25.2) 56.9
DM1-342D2… 2.2 4.3 13 9 56 65 14.83 (25.2) 56.9
DM1-344D3… 4.3 5.6 13 9 62 75 14.83 (25.2) 56.9
DM1-345D6 5.6 7.6 13 9 79 113 14.83 (25.2) 56.9
FR2 DM1-347D6… 7.6 12 22 12 114 150 37.43 (6 3.6) 65.6
DM1-34012… 12 16 22 12 140 203 37.43 (63.6) 65.6
DM1-34016… 16 23 22 12 216.4 332.4 37.4 3 (63.6) 65.6
FR3 DM1-34023.. 23 31 37.7 17.8 282.3 407.4 58.61 (99.6) 64
FR4 DM1-340 31… 31 38 47.5 16.9 296.7 393.8 5 7.56 (97.8) 65.9
DM1-34038… 38 46 47.5 16.9 428.2 473.4 57.56 (97.8) 65.9
525 Vac to 600 Vac
50/60 Hz
3-phase
FR2 DM1-354D5… 4.5 7.5
DM1-357D5… 7.5 10
DM1-35010… 10 13.5
FR3 DM1-35013… 13.5 18
FR4 DM1-35018… 18 22
DM1-35022… 22 27