XS series operating manual 
 
XS user manual v0.55  - 66 - 
 
ANY PARAMETER MODIFICATION IS AUTOMATICALLY STORED IN THE MEMORY  
Expert mode parameters only 
 
[expert] 
 
As explained before, the expert mode gives more controls to the unit to adapt the behavior of the unit 
regarding the user’s need. 
 
Breakdown detection mode selection during the ramps 
 
 
 
Fig 8.13 
 
It is possible to select a breakdown detection mode specifically for the ramps. 
The ramps parameters are valid for the rising and falling ramps together. 
As mentioned before, the breakdown detection modes are :  
I, IMAX+I, IMAX, OFF, FIMAX+I, FIMAX 
 
WARNING 
 
IMAX and IMAX+I  modes involve that the current display is actived and the rising or the 
falling times are greater or equal to 2s