Figure 92. Engine Temperature Operating Envelope
CAUTION:
In order to minimize start ITT, allow engine to windmill until ITT is less than 100°C
before initiating in flight engine restart.
8.3.11 Start Cycle
Engine starters are limited to the following operating/cool-down intervals, both for
engine start and motoring:
Operating Cool-Down
Cycle #1 30 sec 1 min
Cycle #2 30 sec 1 min
Cycle #3 30 sec 30 min
NOTE:
The cycles may be repeated as required.
8.3.12 Battery Start
Minimum Temperature
Battery only engine start..........................................................................5°C / 41°F
Minimum start battery voltage
Battery only engine start..............................................................................23 VDC