Section 8. Engines & Fire Protection Eclipse 5OO Systems Manual
Copyright © — Eclipse Aviation Corporation
156 Version 2.0 April 2007
8.4.9 N2 RPM
Figure 100. N2 Displays- Digital and Tape
N
2
is continuously displayed on the MFD with a digital readout in percent of maximum
RPM and with a moving tape and digital readout on the engine synoptic page. The
scale of the tape is 0 to 105%. An adjacent tape displays N
2
limits. A green band on
the limit tape extends from 45% to 100%. An amber band extends from 100% to
102%. A red band begins at the maximum continuous limit of 102%.
The digital value and moving tape are white for N
2
values in the green band, in amber
for N
2
values in the amber band, and in red for N
2
values above the RPM limit. If the
RPM exceeds the limit for 20 seconds, a L (R) ENG EXCEEDANCE warning
message appears

Table of Contents