The screen displays:
- Quantity of recovered refrigerant, in grams
- The vacuum time performed, in minutes
- The number of days since the last maintenance.
Maintenance Counters
COUNTER
MAXIMUM
THRESHOLD
ACTION
Recovered refrigerant quantity
« g ref recov. »
150 000 g
Replace drier filter
Vacuum time performed
« min vacuum »
6000 Min
Replace vacuum pump oil
Days of use
« days »
365 days
Carry out a yearly maintenance
11.2.2. RAZ Maintenance
This menu allows the counters to be returned to zero after maintenance. It can only be accessed by
authorised maintenance technicians and a password is required.
11.2.3. Counters
The unit’s general counter can only be accessed by the manufacturer and requires a password.
11.3. Units Versions
The unit’s version could be asked in the case of a repair or diagnostic.
From the homepage, access the menu by pressing ENTER.
Select 3.
Select 3.
Screen displays:
- The software version: SW
- Unit version: HW
- Unit's serial number: SN
Press STOP to exit the menu.
11.4. Root settings
This menu can only be accessed by the manufacturer and requires a password.
MAINTENANCE INFO
35284 g ref recycl.
824 min vacuum
158 days
>> MAIN MENU <<
1.ECS Operation
2.History
3.Settings ã
>> SETTINGS <<
1.User settings
2.Maintenance
3.Machine revision
MACHINE REVISION
SW rev: 2001
HW rev: 16/12/2013
SN: 20184